Voltage/Current Regulators
|
||
|
|
||
|
Optional properties:
|
||
|
- regulator-name: A string used as a descriptive name for regulator outputs
|
||
|
- regulator-min-microvolt: smallest voltage consumers may set
|
||
|
- regulator-max-microvolt: largest voltage consumers may set
|
||
|
- regulator-microvolt-offset: Offset applied to voltages to compensate for voltage drops
|
||
|
- regulator-min-microamp: smallest current consumers may set
|
||
|
- regulator-max-microamp: largest current consumers may set
|
||
|
- regulator-input-current-limit-microamp: maximum input current regulator allows
|
||
|
- regulator-always-on: boolean, regulator should never be disabled
|
||
|
- regulator-boot-on: bootloader/firmware enabled regulator
|
||
|
- regulator-allow-bypass: allow the regulator to go into bypass mode
|
||
|
- regulator-allow-set-load: allow the regulator performance level to be configured
|
||
|
- <name>-supply: phandle to the parent supply/regulator node
|
||
|
- regulator-ramp-delay: ramp delay for regulator(in uV/us)
|
||
|
For hardware which supports disabling ramp rate, it should be explicitly
|
||
|
initialised to zero (regulator-ramp-delay = <0>) for disabling ramp delay.
|
||
|
- regulator-enable-ramp-delay: The time taken, in microseconds, for the supply
|
||
|
rail to reach the target voltage, plus/minus whatever tolerance the board
|
||
|
design requires. This property describes the total system ramp time
|
||
|
required due to the combination of internal ramping of the regulator itself,
|
||
|
and board design issues such as trace capacitance and load on the supply.
|
||
|
- regulator-settling-time-us: Settling time, in microseconds, for voltage
|
||
|
change if regulator have the constant time for any level voltage change.
|
||
|
This is useful when regulator have exponential voltage change.
|
||
|
- regulator-settling-time-up-us: Settling time, in microseconds, for voltage
|
||
|
increase if the regulator needs a constant time to settle after voltage
|
||
|
increases of any level. This is useful for regulators with exponential
|
||
|
voltage changes.
|
||
|
- regulator-settling-time-down-us: Settling time, in microseconds, for voltage
|
||
|
decrease if the regulator needs a constant time to settle after voltage
|
||
|
decreases of any level. This is useful for regulators with exponential
|
||
|
voltage changes.
|
||
|
- regulator-soft-start: Enable soft start so that voltage ramps slowly
|
||
|
- regulator-state-mem sub-root node for Suspend-to-RAM mode
|
||
|
: suspend to memory, the device goes to sleep, but all data stored in memory,
|
||
|
only some external interrupt can wake the device.
|
||
|
- regulator-state-disk sub-root node for Suspend-to-DISK mode
|
||
|
: suspend to disk, this state operates similarly to Suspend-to-RAM,
|
||
|
but includes a final step of writing memory contents to disk.
|
||
|
- regulator-state-[mem/disk] node has following common properties:
|
||
|
- regulator-on-in-suspend: regulator should be on in suspend state.
|
||
|
- regulator-off-in-suspend: regulator should be off in suspend state.
|
||
|
- regulator-suspend-min-microvolt: minimum voltage may be set in
|
||
|
suspend state.
|
||
|
- regulator-suspend-max-microvolt: maximum voltage may be set in
|
||
|
suspend state.
|
||
|
- regulator-suspend-microvolt: the default voltage which regulator
|
||
|
would be set in suspend. This property is now deprecated, instead
|
||
|
setting voltage for suspend mode via the API which regulator
|
||
|
driver provides is recommended.
|
||
|
- regulator-changeable-in-suspend: whether the default voltage and
|
||
|
the regulator on/off in suspend can be changed in runtime.
|
||
|
- regulator-mode: operating mode in the given suspend state.
|
||
|
The set of possible operating modes depends on the capabilities of
|
||
|
every hardware so the valid modes are documented on each regulator
|
||
|
device tree binding document.
|
||
|
- regulator-initial-mode: initial operating mode. The set of possible operating
|
||
|
modes depends on the capabilities of every hardware so each device binding
|
||
|
documentation explains which values the regulator supports.
|
||
|
- regulator-allowed-modes: list of operating modes that software is allowed to
|
||
|
configure for the regulator at run-time. Elements may be specified in any
|
||
|
order. The set of possible operating modes depends on the capabilities of
|
||
|
every hardware so each device binding document explains which values the
|
||
|
regulator supports.
|
||
|
- regulator-system-load: Load in uA present on regulator that is not captured by
|
||
|
any consumer request.
|
||
|
- regulator-pull-down: Enable pull down resistor when the regulator is disabled.
|
||
|
- regulator-over-current-protection: Enable over current protection.
|
||
|
- regulator-active-discharge: tristate, enable/disable active discharge of
|
||
|
regulators. The values are:
|
||
|
0: Disable active discharge.
|
||
|
1: Enable active discharge.
|
||
|
Absence of this property will leave configuration to default.
|
||
|
- regulator-coupled-with: Regulators with which the regulator
|
||
|
is coupled. The linkage is 2-way - all coupled regulators should be linked
|
||
|
with each other. A regulator should not be coupled with its supplier.
|
||
|
- regulator-coupled-max-spread: Max spread between voltages of coupled regulators
|
||
|
in microvolts.
|
||
|
|
||
|
Deprecated properties:
|
||
|
- regulator-compatible: If a regulator chip contains multiple
|
||
|
regulators, and if the chip's binding contains a child node that
|
||
|
describes each regulator, then this property indicates which regulator
|
||
|
this child node is intended to configure. If this property is missing,
|
||
|
the node's name will be used instead.
|
||
|
|
||
|
Example:
|
||
|
|
||
|
xyzreg: regulator@0 {
|
||
|
regulator-min-microvolt = <1000000>;
|
||
|
regulator-max-microvolt = <2500000>;
|
||
|
regulator-always-on;
|
||
|
vin-supply = <&vin>;
|
||
|
|
||
|
regulator-state-mem {
|
||
|
regulator-on-in-suspend;
|
||
|
};
|
||
|
};
|
||
|
|
||
|
Regulator Consumers:
|
||
|
Consumer nodes can reference one or more of its supplies/
|
||
|
regulators using the below bindings.
|
||
|
|
||
|
- <name>-supply: phandle to the regulator node
|
||
|
|
||
|
These are the same bindings that a regulator in the above
|
||
|
example used to reference its own supply, in which case
|
||
|
its just seen as a special case of a regulator being a
|
||
|
consumer itself.
|
||
|
|
||
|
Example of a consumer device node (mmc) referencing two
|
||
|
regulators (twl_reg1 and twl_reg2),
|
||
|
|
||
|
twl_reg1: regulator@0 {
|
||
|
...
|
||
|
...
|
||
|
...
|
||
|
};
|
||
|
|
||
|
twl_reg2: regulator@1 {
|
||
|
...
|
||
|
...
|
||
|
...
|
||
|
};
|
||
|
|
||
|
mmc: mmc@0 {
|
||
|
...
|
||
|
...
|
||
|
vmmc-supply = <&twl_reg1>;
|
||
|
vmmcaux-supply = <&twl_reg2>;
|
||
|
};
|