kernel_samsung_a34x-permissive/Documentation/devicetree/bindings/interrupt-controller/samsung,s3c24xx-irq.txt
2024-04-28 15:49:01 +02:00

54 lines
1.6 KiB
Plaintext
Executable file

Samsung S3C24XX Interrupt Controllers
The S3C24XX SoCs contain a custom set of interrupt controllers providing a
varying number of interrupt sources. The set consists of a main- and sub-
controller and on newer SoCs even a second main controller.
Required properties:
- compatible: Compatible property value should be "samsung,s3c2410-irq"
for machines before s3c2416 and "samsung,s3c2416-irq" for s3c2416 and later.
- reg: Physical base address of the controller and length of memory mapped
region.
- interrupt-controller : Identifies the node as an interrupt controller
- #interrupt-cells : Specifies the number of cells needed to encode an
interrupt source. The value shall be 4 and interrupt descriptor shall
have the following format:
<ctrl_num parent_irq ctrl_irq type>
ctrl_num contains the controller to use:
- 0 ... main controller
- 1 ... sub controller
- 2 ... second main controller on s3c2416 and s3c2450
parent_irq contains the parent bit in the main controller and will be
ignored in main controllers
ctrl_irq contains the interrupt bit of the controller
type contains the trigger type to use
Example:
interrupt-controller@4a000000 {
compatible = "samsung,s3c2410-irq";
reg = <0x4a000000 0x100>;
interrupt-controller;
#interrupt-cells=<4>;
};
[...]
serial@50000000 {
compatible = "samsung,s3c2410-uart";
reg = <0x50000000 0x4000>;
interrupt-parent = <&subintc>;
interrupts = <1 28 0 4>, <1 28 1 4>;
};
rtc@57000000 {
compatible = "samsung,s3c2410-rtc";
reg = <0x57000000 0x100>;
interrupt-parent = <&intc>;
interrupts = <0 30 0 3>, <0 8 0 3>;
};