kernel_samsung_a34x-permissive/Documentation/devicetree/bindings/sound/mt6797-afe-pcm.txt
2024-04-28 15:49:01 +02:00

43 lines
1.2 KiB
Plaintext
Executable file

Mediatek AFE PCM controller for mt6797
Required properties:
- compatible = "mediatek,mt6797-audio";
- reg: register location and size
- interrupts: should contain AFE interrupt
- power-domains: should define the power domain
- clocks: Must contain an entry for each entry in clock-names
- clock-names: should have these clock names:
"infra_sys_audio_clk",
"infra_sys_audio_26m",
"mtkaif_26m_clk",
"top_mux_audio",
"top_mux_aud_intbus",
"top_sys_pll3_d4",
"top_sys_pll1_d4",
"top_clk26m_clk";
Example:
afe: mt6797-afe-pcm@11220000 {
compatible = "mediatek,mt6797-audio";
reg = <0 0x11220000 0 0x1000>;
interrupts = <GIC_SPI 151 IRQ_TYPE_LEVEL_LOW>;
power-domains = <&scpsys MT6797_POWER_DOMAIN_AUDIO>;
clocks = <&infrasys CLK_INFRA_AUDIO>,
<&infrasys CLK_INFRA_AUDIO_26M>,
<&infrasys CLK_INFRA_AUDIO_26M_PAD_TOP>,
<&topckgen CLK_TOP_MUX_AUDIO>,
<&topckgen CLK_TOP_MUX_AUD_INTBUS>,
<&topckgen CLK_TOP_SYSPLL3_D4>,
<&topckgen CLK_TOP_SYSPLL1_D4>,
<&clk26m>;
clock-names = "infra_sys_audio_clk",
"infra_sys_audio_26m",
"mtkaif_26m_clk",
"top_mux_audio",
"top_mux_aud_intbus",
"top_sys_pll3_d4",
"top_sys_pll1_d4",
"top_clk26m_clk";
};